Below you will find a list of common error messages from various brands. Not all error messages are listed here. It is advisable to also consult the manual of the device.

Brand Error code Cause Action
______________ ____________________________ _________________________ ________________________________________________________
Omnik Ground I Fault GFCI failure oversized leakage current Please check the DC wiring and measure. If you consider the wiring to be in order, contact inverter service
Omnik Fac Failure Grid frequency failure Please check the AC wiring and measure. If you consider the wiring to be in order, contact inverter service
Omnik Vac Failure Grid voltage failure Please check the AC wiring and measure. If you consider the wiring to be in order, contact inverter service
Omnik Utility Loss No Utility&Island Please check the AC wiring and measure. If you consider the wiring to be in order, contact inverter service
Omnik PV Over Voltage Input voltage too high Please check the DC wiring and measure. If you consider the wiring to be in order, contact inverter service
Omnik Over Temperature Temperature abnormal Check the inverter for heat build up or blockage of the cooler ribs and rectify as required. If this does not correct the problem, contact inverter service
Omnik Isolation Fault Isolation failure Check system isolation. If you consider the isolation impedance to be in order, contact inverter service
Omnik Relay-Check Fail Output relay failure If problem occurs repeatedly, contact inverter service
Omnik DC INJ High Output DC injection too high If problem occurs repeatedly, contact inverter service
Omnik EEPROM R/W Fail EEPROM problem If problem occurs repeatedly, contact inverter service
Omnik SCI Failure Serial communication interface failure Please contact inverter service
Omnik AC HCT Failure Output AC sensor abnormal If problem occurs repeatedly, contact inverter service
Omnik GFCI Failure GFCI testing device abnormal If problem occurs repeatedly, contact inverter service
Omnik /W Updating Update If problem occurs once only: wait for the regulator to be come stable again. If problem occurs repeatedly: please contact inverter service
Omnik Reconnect s Reconnect This text is displayed for information purposes only.
Omnik Checking s Checking This text is displayed for information purposes only.
Omnik Waiting Initialization & waiting This text is displayed for information purposes only.